Celesco PT8510 · Low-Profile Cable-Extension Sensor · voltage output (0–10 / 0–5 / ±10 / ±5 VDC) · 2–60 in. stroke
The Celesco PT8510 is the voltage-output member of the low-profile PT8000 family. It orders as PT8510 – RRRR – A B C – D E F G. A combines the enclosure material (aluminum / 303 / 316 stainless) with the cable tension, and E selects one of eight bidirectional voltage-output ranges. Example: PT8510-0030-111-1110 = 30-inch range, aluminum enclosure standard tension, 0–10 VDC output, 6-pin plastic connector, standard nylon cable guide.
PT8510–0060–111–1110ModelRangeOptionsSignal / Connection
Order Code Table
R · Full Stroke Range
| Code | Meaning |
| 0002 | 2 in. |
| 0005 | 5 in. |
| 0010 | 10 in. |
| 0015 | 15 in. |
| 0020 | 20 in. |
| 0025 | 25 in. |
| 0030 | 30 in. |
| 0040 | 40 in. |
| 0050 | 50 in. |
| 0060 | 60 in. |
A · Enclosure Material & Cable Tension
| Code | Meaning |
| 1 | Aluminum enclosure, standard tension (±50%) — max acceleration 15 g |
| 5 | Aluminum enclosure, medium tension — max acceleration 25 g |
| 2 | Aluminum enclosure, high tension — max acceleration 40 g |
| 3 | 303 stainless enclosure, standard tension — max acceleration 6 g |
| 6 | 303 stainless enclosure, medium tension — max acceleration 12 g |
| 4 | 303 stainless enclosure, high tension — max acceleration 18 g |
| 8 | 316 stainless enclosure, standard tension — max acceleration 6 g |
| 7 | 316 stainless enclosure, medium tension — max acceleration 12 g |
| 9 | 316 stainless enclosure, high tension — max acceleration 18 g |
B · Measuring Cable
| Code | Meaning |
| 1 | Ø.034-inch nylon-coated stainless rope — all ranges, indoor use |
| 2 | Ø.047-inch bare stainless rope — 5/15/20/25/30 in. only, outdoor, debris & high temperature |
| 3 | Ø.058-inch PVC-jacketed fiber rope — thru 30 in. only, high voltage or magnetic field use |
| 4 | Ø.031-inch bare stainless rope — 40/50/60 in. only, outdoor, debris & high temperature |
C · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
D · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
E · Output Signal (voltage)
| Code | Meaning |
| 1 | 0…10 VDC (input 14.5–40 VDC) |
| 2 | 10…0 VDC (input 14.5–40 VDC) |
| 3 | 0…5 VDC (input 10.5–40 VDC) |
| 4 | 5…0 VDC (input 10.5–40 VDC) |
| 5 | -10…+10 VDC (input 14.5–40 VDC) |
| 6 | +10…-10 VDC (input 14.5–40 VDC) |
| 7 | -5…+5 VDC (input 10.5–40 VDC) |
| 8 | +5…-5 VDC (input 10.5–40 VDC) |
F · Electrical Connection
| Code | Meaning |
| 1 | 6-pin plastic connector w/ mating plug — IP 67, NEMA 4/4X/6 |
| 2 | 10-ft [3 M] waterproof cable — IP 67, NEMA 4X, 3-conductor 18 AWG |
| 3 | 6-pin metal connector w/ mating plug — IP 65, NEMA 4 |
| 4 | 25-ft [7.5 M] instrumentation cable, 24 AWG shielded — IP 67, NEMA 6 |
| 5 | 100-ft [30 M] waterproof cable — IP 67, NEMA 4X/6, 18 AWG |
| 6 | 10-ft [3 M] pressure-tested waterproof cable — IP 68, NEMA 4X/6P |
| 7 | 100-ft [30 M] pressure-tested waterproof cable — IP 68, NEMA 4X/6P |
G · Cable Guide Option
| Code | Meaning |
| 0 | Standard nylon cable guide |
Special Options & Notes
- Voltage-output cousin of the PT8420 (4–20 mA): same enclosure/tension codes, but E selects a bidirectional voltage range instead of current loops.
- Bare stainless and PVC cable options are limited to specific stroke ranges — see the B code availability notes.
- Pressure-tested cable options (F = 6/7) are rated IP 68 for submersion; 100-ft options add ~1.8 s span-adjustment response.
- VLS8510 codes use the same structure with the VLS (Velocity Limiting System) free-release protection.
Frequently Asked Questions
What does PT8510-0060-111-1110 mean?
A Celesco PT8510 with 60-inch stroke (0060), aluminum enclosure with standard tension (1), Ø.034-inch nylon-coated stainless measuring cable (1), 0–10 VDC voltage output (1) and a 6-pin plastic connector (1), with the standard nylon cable guide (0).
What does the A digit on a PT8510 combine?
One digit selects both the enclosure material and the cable tension: 1/5/2 = aluminum with standard/medium/high tension, 3/6/4 = 303 stainless, 8/7/9 = 316 stainless. Higher tension ratings allow higher retraction acceleration (6 g up to 40 g).
How is the PT8510 different from the PT8420?
Both share the low-profile PT8000 housing and the same R/A/B code structure. The PT8510 outputs a voltage signal (0–10, 0–5, ±10, ±5 VDC, selectable in both directions), while the PT8420 outputs current loops (4–20 mA etc.). Choose the PT8510 when your PLC takes voltage inputs.
Found your part number?
Send it to KMBT for a quotation — Celesco cable-extension and rotary position sensors with fast lead times and full datasheets.