PT9101 Part Number Decoder & How to Order

The Celesco PT9101 is the potentiometer-output version of the PT9420. Order code: PT9101 – RRRR – A B C – D E F G, where D selects the sensing circuit (500 Ω to 10 KΩ pot, or 2 mV/V bridge). Example: PT9101-0100-114-3160 = 100-inch range, aluminum/18 oz, Ø.034" cable, bottom exit, 5000 Ω potentiometer, 10 ft. pressure-tested waterproof cable.

PT9101–0100–114–3160ModelRangeOptionsSignal / Connection

Part Number Decoder

Paste any order code — with or without dashes (PT9420-0350-424-1110 or PT942003504241110).

Try:

Order Code Table

R · Full Stroke Range

CodeMeaning
007575 in.
0100100 in.
0150150 in.
0200200 in.
0250250 in.
0300300 in.
0350350 in.
0400400 in.
0450450 in. (36 oz tension recommended)
0500500 in. (36 oz recommended)
0550550 in. (36 oz recommended)

A · Enclosure Material & Cable Tension

CodeMeaning
1Powder-painted aluminum, 18 oz tension (standard housing)
2Powder-painted aluminum, 36 oz tension (dual-spring housing)
3303 stainless steel, 18 oz tension (standard housing)
4303 stainless steel, 36 oz tension (dual-spring housing)

B · Measuring Cable

CodeMeaning
1Ø.034" nylon-coated stainless rope — all ranges — general indoor use
2Ø.047" bare stainless rope — up to 500 in. — outdoor / debris / high temperature
3Ø.058" PVC-jacketed vectra fiber rope — up to 400 in. — high voltage or magnetic field areas
4Ø.031" bare stainless rope — 550 in. range only — outdoor / debris / high temperature

C · Cable Exit

CodeMeaning
1Front
2Top
3Back
4Down

D · Sensing Circuit

CodeMeaning
1500 Ω potentiometer (tolerance ±10%)
21000 Ω potentiometer (±10%)
35000 Ω potentiometer (±10%)
410,000 Ω potentiometer (±10%)
5Fixed bridge, 2 mV/V full scale
6Adjustable bridge, 0…30 mV/V (zero adjustable to 50% FS)

E · Reserved

CodeMeaning
1Fixed digit (reserved position)

F · Electrical Connection

CodeMeaning
16-pin plastic connector with mating plug — IP67, NEMA 4X/6
210 ft. [3 m] waterproof cable — IP67, NEMA 4X/6
36-pin metal connector with mating plug — IP65, NEMA 4
425 ft. [7.5 m] instrumentation cable, 24 AWG shielded — IP67, NEMA 4X/6
5100 ft. [30 m] waterproof cable — IP67, NEMA 4X/6
610 ft. [3 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P
7100 ft. [30 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P

G · Reserved

CodeMeaning
0Fixed digit (reserved position)

Special Options & Notes

  • VLS option available: replace PT with VLS (e.g. VLS9101-0100-111-1110).
  • EX suffix (PT9101EX): explosion-proof variant with its own ordering table.

Frequently Asked Questions

What does PT9101-0100-114-3160 mean?

A Celesco PT9101 with 100-inch stroke (0100), aluminum enclosure with 18 oz tension (1), Ø.034" nylon-coated stainless cable (1), bottom cable exit (4), 5000 Ω potentiometer sensing circuit (3) and 10 ft. pressure-tested waterproof cable rated IP68/NEMA 6P (6).

Which PT9101 sensing circuit should I order?

Options 1–4 are potentiometers from 500 Ω to 10 KΩ — ideal for direct voltage-divider readings. Option 5 is a fixed 2 mV/V bridge for ratiometric A/D inputs; option 6 is an adjustable 0–30 mV/V bridge when you need to match a specific span.

How does PT9101 differ from PT9420?

Identical mechanics and option structure, but the PT9101 outputs a resistance (500 Ω–10 KΩ pot or mV/V bridge) while the PT9420 outputs a 4–20 mA / 0–20 mA current loop signal. In the code, the difference sits in the D digit (sensing circuit) versus the E digit (current output).

Found your part number?

Send it to KMBT for a quotation — Celesco cable-extension and rotary position sensors with fast lead times and full datasheets.