DV301 Part Number Decoder & How to Order

The Celesco DV301 combines a precision potentiometer (position) with a DC tachometer (velocity) in one housing. It orders as DV301 – RRRR – A D F (range, cable tension, output impedance, connector). Example: DV301-0060-111 = 60-inch range, standard tension, 500 Ω pot, 6-pin plastic connector. Older 11-digit codes (e.g. DV301-0060-211-1110) decode the same way — extra digits are reserved positions.

DV301–0060–211–1110ModelRangeOptionsSignal / Connection

Part Number Decoder

Paste any order code — with or without dashes (PT9420-0350-424-1110 or PT942003504241110).

Try:

Order Code Table

R · Full Stroke Range

CodeMeaning
00022 in.
00055 in.
001010 in.
001515 in.
002020 in.
002525 in.
003030 in.
004040 in.
005050 in.
006060 in.
007575 in.
0100100 in.

A · Measuring Cable Tension

CodeMeaning
1Standard tension (±30%) — e.g. 39 oz at 2–20 in., 16 oz at 5–50 in.
HHigh tension (±40%) — e.g. 65 oz at 2–20 in., 26 oz at 5–50 in.
MMax tension (±40%) — e.g. 116 oz at 2–20 in., 47 oz at 5–50 in.

B · Reserved

CodeMeaning
1Fixed digit (reserved position)

C · Reserved

CodeMeaning
1Fixed digit (reserved position)

D · Output Signal (position potentiometer)

CodeMeaning
1500 Ω potentiometer (±10%)
21000 Ω potentiometer (±10%)
35000 Ω potentiometer (±10%)
410,000 Ω potentiometer (±10%)

E · Reserved

CodeMeaning
1Fixed digit (reserved position)

F · Electrical Connection

CodeMeaning
16-pin plastic connector with mating plug (MS3102E-14S-6P / MS3106E-14S-6S)
36-pin metal connector with mating plug (MS3102E-14S-6P / MS3106E-14S-6S)
425 ft. [7.5 m] instrumentation cable, 24 AWG shielded

G · Reserved

CodeMeaning
0Fixed digit (reserved position)

Special Options & Notes

  • The velocity output is a self-generating DC tachometer — no input voltage required; output voltage at 100 in./min depends on the range code (66–322 mV).
  • Cable tension option 2 or 3 in legacy 11-digit codes reduces the velocity output signal by 50%.
  • Codes with digits that don't match the tables above are factory specials or distributor stock numbers — contact us with the full code.

Frequently Asked Questions

What does DV301-0060-211-1110 mean?

A Celesco DV301 position + velocity transducer with 60-inch stroke (0060). In the legacy 11-digit code the following digits are reserved positions; the meaningful digits select the cable tension, the 500–10,000 Ω position potentiometer and the electrical connector. The official short form is DV301-0060-A-D-F (e.g. DV301-0060-1-1-1 = 60 in., standard tension, 500 Ω pot, 6-pin plastic connector).

Does the DV301 need a power supply for the velocity signal?

No. The velocity channel is a self-generating DC tachometer — it produces a voltage proportional to cable speed with no input voltage. Only the position potentiometer needs an excitation voltage (see the D order code for the max input rating).

What is the difference between the 1, H and M tension options?

They set how hard the measuring cable is pulled back. 1 = standard tension (±30%), H = high tension (±40%), M = max tension (±40%) — e.g. on a 2–20 in. range: 39 oz / 65 oz / 116 oz. Higher tension improves cable tautness at high acceleration but adds load on the application.

Found your part number?