Celesco DV301 · Combination Position + Velocity Sensor · potentiometer + DC tachometer · 2–100 in. stroke
The Celesco DV301 combines a precision potentiometer (position) with a DC tachometer (velocity) in one housing. It orders as DV301 – RRRR – A D F (range, cable tension, output impedance, connector). Example: DV301-0060-111 = 60-inch range, standard tension, 500 Ω pot, 6-pin plastic connector. Older 11-digit codes (e.g. DV301-0060-211-1110) decode the same way — extra digits are reserved positions.
DV301–0060–211–1110ModelRangeOptionsSignal / Connection
Order Code Table
R · Full Stroke Range
| Code | Meaning |
| 0002 | 2 in. |
| 0005 | 5 in. |
| 0010 | 10 in. |
| 0015 | 15 in. |
| 0020 | 20 in. |
| 0025 | 25 in. |
| 0030 | 30 in. |
| 0040 | 40 in. |
| 0050 | 50 in. |
| 0060 | 60 in. |
| 0075 | 75 in. |
| 0100 | 100 in. |
A · Measuring Cable Tension
| Code | Meaning |
| 1 | Standard tension (±30%) — e.g. 39 oz at 2–20 in., 16 oz at 5–50 in. |
| H | High tension (±40%) — e.g. 65 oz at 2–20 in., 26 oz at 5–50 in. |
| M | Max tension (±40%) — e.g. 116 oz at 2–20 in., 47 oz at 5–50 in. |
B · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
C · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
D · Output Signal (position potentiometer)
| Code | Meaning |
| 1 | 500 Ω potentiometer (±10%) |
| 2 | 1000 Ω potentiometer (±10%) |
| 3 | 5000 Ω potentiometer (±10%) |
| 4 | 10,000 Ω potentiometer (±10%) |
E · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
F · Electrical Connection
| Code | Meaning |
| 1 | 6-pin plastic connector with mating plug (MS3102E-14S-6P / MS3106E-14S-6S) |
| 3 | 6-pin metal connector with mating plug (MS3102E-14S-6P / MS3106E-14S-6S) |
| 4 | 25 ft. [7.5 m] instrumentation cable, 24 AWG shielded |
G · Reserved
| Code | Meaning |
| 0 | Fixed digit (reserved position) |
Special Options & Notes
- The velocity output is a self-generating DC tachometer — no input voltage required; output voltage at 100 in./min depends on the range code (66–322 mV).
- Cable tension option 2 or 3 in legacy 11-digit codes reduces the velocity output signal by 50%.
- Codes with digits that don't match the tables above are factory specials or distributor stock numbers — contact us with the full code.
Frequently Asked Questions
What does DV301-0060-211-1110 mean?
A Celesco DV301 position + velocity transducer with 60-inch stroke (0060). In the legacy 11-digit code the following digits are reserved positions; the meaningful digits select the cable tension, the 500–10,000 Ω position potentiometer and the electrical connector. The official short form is DV301-0060-A-D-F (e.g. DV301-0060-1-1-1 = 60 in., standard tension, 500 Ω pot, 6-pin plastic connector).
Does the DV301 need a power supply for the velocity signal?
No. The velocity channel is a self-generating DC tachometer — it produces a voltage proportional to cable speed with no input voltage. Only the position potentiometer needs an excitation voltage (see the D order code for the max input rating).
What is the difference between the 1, H and M tension options?
They set how hard the measuring cable is pulled back. 1 = standard tension (±30%), H = high tension (±40%), M = max tension (±40%) — e.g. on a 2–20 in. range: 39 oz / 65 oz / 116 oz. Higher tension improves cable tautness at high acceleration but adds load on the application.
Found your part number?
Send it to KMBT for a quotation — Celesco cable-extension and rotary position sensors with fast lead times and full datasheets.