Celesco PT9000 Series · Cable-Extension Sensor · 500 Ω – 10 KΩ potentiometer / bridge output · 75–550 in. stroke
The Celesco PT9101 is the potentiometer-output version of the PT9420. Order code: PT9101 – RRRR – A B C – D E F G, where D selects the sensing circuit (500 Ω to 10 KΩ pot, or 2 mV/V bridge). Example: PT9101-0100-114-3160 = 100-inch range, aluminum/18 oz, Ø.034" cable, bottom exit, 5000 Ω potentiometer, 10 ft. pressure-tested waterproof cable.
PT9101–0100–114–3160ModelRangeOptionsSignal / Connection
Order Code Table
R · Full Stroke Range
| Code | Meaning |
| 0075 | 75 in. |
| 0100 | 100 in. |
| 0150 | 150 in. |
| 0200 | 200 in. |
| 0250 | 250 in. |
| 0300 | 300 in. |
| 0350 | 350 in. |
| 0400 | 400 in. |
| 0450 | 450 in. (36 oz tension recommended) |
| 0500 | 500 in. (36 oz recommended) |
| 0550 | 550 in. (36 oz recommended) |
A · Enclosure Material & Cable Tension
| Code | Meaning |
| 1 | Powder-painted aluminum, 18 oz tension (standard housing) |
| 2 | Powder-painted aluminum, 36 oz tension (dual-spring housing) |
| 3 | 303 stainless steel, 18 oz tension (standard housing) |
| 4 | 303 stainless steel, 36 oz tension (dual-spring housing) |
B · Measuring Cable
| Code | Meaning |
| 1 | Ø.034" nylon-coated stainless rope — all ranges — general indoor use |
| 2 | Ø.047" bare stainless rope — up to 500 in. — outdoor / debris / high temperature |
| 3 | Ø.058" PVC-jacketed vectra fiber rope — up to 400 in. — high voltage or magnetic field areas |
| 4 | Ø.031" bare stainless rope — 550 in. range only — outdoor / debris / high temperature |
C · Cable Exit
| Code | Meaning |
| 1 | Front |
| 2 | Top |
| 3 | Back |
| 4 | Down |
D · Sensing Circuit
| Code | Meaning |
| 1 | 500 Ω potentiometer (tolerance ±10%) |
| 2 | 1000 Ω potentiometer (±10%) |
| 3 | 5000 Ω potentiometer (±10%) |
| 4 | 10,000 Ω potentiometer (±10%) |
| 5 | Fixed bridge, 2 mV/V full scale |
| 6 | Adjustable bridge, 0…30 mV/V (zero adjustable to 50% FS) |
E · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
F · Electrical Connection
| Code | Meaning |
| 1 | 6-pin plastic connector with mating plug — IP67, NEMA 4X/6 |
| 2 | 10 ft. [3 m] waterproof cable — IP67, NEMA 4X/6 |
| 3 | 6-pin metal connector with mating plug — IP65, NEMA 4 |
| 4 | 25 ft. [7.5 m] instrumentation cable, 24 AWG shielded — IP67, NEMA 4X/6 |
| 5 | 100 ft. [30 m] waterproof cable — IP67, NEMA 4X/6 |
| 6 | 10 ft. [3 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P |
| 7 | 100 ft. [30 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P |
G · Reserved
| Code | Meaning |
| 0 | Fixed digit (reserved position) |
Special Options & Notes
- VLS option available: replace PT with VLS (e.g. VLS9101-0100-111-1110).
- EX suffix (PT9101EX): explosion-proof variant with its own ordering table.
Frequently Asked Questions
What does PT9101-0100-114-3160 mean?
A Celesco PT9101 with 100-inch stroke (0100), aluminum enclosure with 18 oz tension (1), Ø.034" nylon-coated stainless cable (1), bottom cable exit (4), 5000 Ω potentiometer sensing circuit (3) and 10 ft. pressure-tested waterproof cable rated IP68/NEMA 6P (6).
Which PT9101 sensing circuit should I order?
Options 1–4 are potentiometers from 500 Ω to 10 KΩ — ideal for direct voltage-divider readings. Option 5 is a fixed 2 mV/V bridge for ratiometric A/D inputs; option 6 is an adjustable 0–30 mV/V bridge when you need to match a specific span.
How does PT9101 differ from PT9420?
Identical mechanics and option structure, but the PT9101 outputs a resistance (500 Ω–10 KΩ pot or mV/V bridge) while the PT9420 outputs a 4–20 mA / 0–20 mA current loop signal. In the code, the difference sits in the D digit (sensing circuit) versus the E digit (current output).
Found your part number?
Send it to KMBT for a quotation — Celesco cable-extension and rotary position sensors with fast lead times and full datasheets.