How to Order

PT8420 Part Number Decoder & How to Order

The Celesco PT8420 order code is PT8420 – RRRR – A B C – D E F G. Its A digit covers nine enclosure/tension combinations (aluminum, 303 SS or 316 SS × standard/medium/high tension), and G selects the cable guide. Example: PT8420-0020-221-1130 = 20-inch range, aluminum high-tension, Ø.047" bare stainless cable, 0–20 mA 3-wire output, 25 ft instrumentation cable, standard cable guide.

PT8420–0020–221–1130ModelRangeOptionsSignal / Connection

Part Number Decoder

Paste any order code — with or without dashes (PT9420-0350-424-1110 or PT942003504241110).

Try:

Order Code Table

R · Full Stroke Range

CodeMeaning
00022 in. (accuracy 1.00%)
00055 in. (1.00%)
001010 in. (0.18%)
001515 in. (0.18%)
002020 in. (0.18%)
002525 in. (0.18%)
003030 in. (0.18%)
004040 in. (0.15%)
005050 in. (0.15%)
006060 in. (0.15%)

A · Enclosure Material & Cable Tension

CodeMeaning
1Aluminum, standard tension
5Aluminum, medium tension
2Aluminum, high tension
3303 stainless steel, standard tension
6303 stainless steel, medium tension
4303 stainless steel, high tension
8316 stainless steel, standard tension
7316 stainless steel, medium tension
9316 stainless steel, high tension

B · Measuring Cable

CodeMeaning
1Ø.034" nylon-coated stainless rope — all ranges — general indoor use
2Ø.047" bare stainless rope — 5/15/20/25/30 in. ranges — outdoor / debris / high temperature
3Ø.058" PVC-jacketed vectra fiber rope — up to 30 in. — high voltage or magnetic field areas
4Ø.031" bare stainless rope — 40/50/60 in. ranges — outdoor / debris / high temperature

C · Reserved

CodeMeaning
1Fixed digit (reserved position)

D · Reserved

CodeMeaning
1Fixed digit (reserved position)

E · Output Signal

CodeMeaning
14…20 mA, 2-wire (8–34 VDC)
220…4 mA, 2-wire (8–34 VDC)
30…20 mA, 3-wire (14–29 VDC)
420…0 mA, 3-wire (14–29 VDC)
54…20 mA, 2-wire, intrinsically safe (CSA / Cenelec certified)
620…4 mA, 2-wire, intrinsically safe (CSA / Cenelec certified)

F · Electrical Connection

CodeMeaning
16-pin plastic connector with mating plug — IP67, NEMA 4X/6
210 ft. [3 m] waterproof cable — IP67, NEMA 4X/6
36-pin metal connector with mating plug — IP65, NEMA 4
425 ft. [7.5 m] instrumentation cable, 24 AWG shielded — IP67, NEMA 4X/6
5100 ft. [30 m] waterproof cable — IP67, NEMA 4X/6
610 ft. [3 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P
7100 ft. [30 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P

G · Cable Guide Option

CodeMeaning
0Standard nylon cable guide
1Stainless steel cable guide
2Polyurethane cable bellows
3Integral cable brush

Special Options & Notes

  • VLS option: ordering code starts with VLS instead of PT (e.g. VLS8420-0060-111-1110) — Velocity Limiting System free-release protection. Not available with medium/high tension, stainless enclosure, bellows guide, or 2/5/15-inch ranges.
  • Actual cable tension depends on range: e.g. standard tension is 13 oz at 30 in., 39 oz at 2 in., 16 oz at 50 in. See the PT8420 datasheet tension table.

Frequently Asked Questions

What does PT8420-0025-721-1453 mean?

A Celesco PT8420 with 25-inch stroke (0025), 316 stainless steel enclosure with medium cable tension (7), Ø.047" bare stainless measuring cable (2), 20–0 mA 3-wire output (4), 100 ft. waterproof cable (5) and integral cable brush (3).

What is the difference between PT8420 and PT9420?

Both are 4–20 mA cable-extension sensors. The PT8420 is the short-stroke heavy-industrial version (2–60 in.) with nine enclosure/tension combinations including 316 stainless steel and a cable-guide option; the PT9420 covers long strokes from 75 to 550 inches.

What is the VLS8420?

A PT8420 fitted with Celesco's Velocity Limiting System (VLS), which limits cable retraction to a safe 40–55 in./sec if the cable is accidentally released. Order it by replacing the PT prefix with VLS, e.g. VLS8420-0060-111-1110.

Found your part number?

Send it to KMBT for a quotation — Celesco cable-extension and rotary position sensors with fast lead times and full datasheets.