How to Order

PT8101 Part Number Decoder & How to Order

The Celesco PT8101 is the potentiometer-output version of the PT8420: PT8101 – RRRR – A B C – D E F G, with the same nine enclosure/tension A codes and cable-guide G digit. Example: PT8101-0040-311-4130 = 40-inch range, 303 stainless/standard tension, Ø.034" cable, 10 KΩ potentiometer, 25 ft instrumentation cable.

PT8101–0040–311–4130ModelRangeOptionsSignal / Connection

Part Number Decoder

Paste any order code — with or without dashes (PT9420-0350-424-1110 or PT942003504241110).

Try:

Order Code Table

R · Full Stroke Range

CodeMeaning
00022 in.
00055 in.
001010 in.
001515 in.
002020 in.
002525 in.
003030 in.
004040 in.
005050 in.
006060 in.

A · Enclosure Material & Cable Tension

CodeMeaning
1Aluminum, standard tension
5Aluminum, medium tension
2Aluminum, high tension
3303 stainless steel, standard tension
6303 stainless steel, medium tension
4303 stainless steel, high tension
8316 stainless steel, standard tension
7316 stainless steel, medium tension
9316 stainless steel, high tension

B · Measuring Cable

CodeMeaning
1Ø.034" nylon-coated stainless rope — all ranges — general indoor use
2Ø.047" bare stainless rope — 5/15/20/25/30 in. ranges — outdoor / debris / high temperature
3Ø.058" PVC-jacketed vectra fiber rope — up to 30 in. — high voltage or magnetic field areas
4Ø.031" bare stainless rope — 40/50/60 in. ranges — outdoor / debris / high temperature

C · Reserved

CodeMeaning
1Fixed digit (reserved position)

D · Sensing Circuit

CodeMeaning
1500 Ω potentiometer (tolerance ±10%)
21000 Ω potentiometer (±10%)
35000 Ω potentiometer (±10%)
410,000 Ω potentiometer (±10%)
5Fixed bridge, 2 mV/V full scale
6Adjustable bridge, 0…30 mV/V

E · Reserved

CodeMeaning
1Fixed digit (reserved position)

F · Electrical Connection

CodeMeaning
16-pin plastic connector with mating plug — IP67, NEMA 4X/6
210 ft. [3 m] waterproof cable — IP67, NEMA 4X/6
36-pin metal connector with mating plug — IP65, NEMA 4
425 ft. [7.5 m] instrumentation cable, 24 AWG shielded — IP67, NEMA 4X/6
5100 ft. [30 m] waterproof cable — IP67, NEMA 4X/6
610 ft. [3 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P
7100 ft. [30 m] pressure-tested waterproof cable — IP68, NEMA 4X/6P

G · Cable Guide Option

CodeMeaning
0Standard nylon cable guide
1Stainless steel cable guide
2Polyurethane cable bellows
3Integral cable brush

Special Options & Notes

  • Actual cable tension depends on range (e.g. standard tension 39 oz at 2 in., 13 oz at 30 in.); see the PT8101 datasheet tension table.

Frequently Asked Questions

What does PT8101-0040-311-4130 mean?

A Celesco PT8101 with 40-inch stroke (0040), 303 stainless steel enclosure with standard tension (3), Ø.034" nylon-coated cable (1), 10,000 Ω potentiometer output (4), 25 ft. instrumentation cable (3) and standard nylon cable guide (0).

How does PT8101 differ from PT8420?

Same housing, ranges (2–60 in.) and option structure. The PT8101 outputs resistance (500 Ω–10 KΩ potentiometer or mV/V bridge); the PT8420 outputs a 4–20 mA / 0–20 mA current loop.

Which cable guide option should I choose?

Code 0 (standard nylon) suits most uses. Code 1 (stainless steel guide) for corrosive or high-wear areas, code 2 (polyurethane bellows) to keep debris off the cable, code 3 (integral cable brush) for heavy particulate environments.

Found your part number?

Send it to KMBT for a quotation — Celesco cable-extension and rotary position sensors with fast lead times and full datasheets.