Celesco PT101 · Compact Cable-Extension Sensor · 500 Ω – 10 KΩ potentiometer / bridge output · 2–100 in. stroke
The compact Celesco PT101 orders as PT101 – RRRR – A B C – D E F G. The A digit is simply standard or high cable tension, and C selects one of four exit positions. Example: PT101-0100-111-2130 = 100-inch range, standard tension, top exit, 1000 Ω potentiometer, 6-pin metal connector.
PT101–0100–111–2130ModelRangeOptionsSignal / Connection
Order Code Table
R · Full Stroke Range
| Code | Meaning |
| 0002 | 2 in. |
| 0005 | 5 in. |
| 0010 | 10 in. |
| 0015 | 15 in. |
| 0020 | 20 in. |
| 0025 | 25 in. |
| 0030 | 30 in. |
| 0040 | 40 in. |
| 0050 | 50 in. |
| 0060 | 60 in. |
| 0075 | 75 in. |
| 0100 | 100 in. |
A · Measuring Cable Tension
| Code | Meaning |
| 1 | Standard tension (±20%) — e.g. 5 oz at 5 in., 13 oz at 60 in., 13 oz at 100 in. |
| H | High tension (±40%) — e.g. 26 oz at 5 in., 22 oz at 60 in., 52 oz at 100 in. |
B · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
C · Cable Exit
| Code | Meaning |
| 1 | Top exit |
| 2 | Front exit |
| 3 | Rear exit |
| 4 | Bottom exit |
D · Sensing Circuit
| Code | Meaning |
| 1 | 500 Ω potentiometer (tolerance ±10%) |
| 2 | 1000 Ω potentiometer (±10%) |
| 3 | 5000 Ω potentiometer (±10%) |
| 4 | 10,000 Ω potentiometer (±10%) |
| 5 | Fixed bridge, 2 mV/V full scale |
| 6 | Adjustable bridge, 0…30 mV/V |
E · Reserved
| Code | Meaning |
| 1 | Fixed digit (reserved position) |
F · Electrical Connection
| Code | Meaning |
| 1 | 6-pin plastic connector with mating plug |
| 2 | Terminal strip |
| 3 | 6-pin metal connector with mating plug |
| 4 | 25 ft. [7.5 m] instrumentation cable, 24 AWG shielded |
G · Reserved
| Code | Meaning |
| 0 | Fixed digit (reserved position) |
Special Options & Notes
- Numbers with extra trailing digits (e.g. PT101-0030-311-6110-8379) are factory specials or distributor stock numbers — contact us with the full code.
Frequently Asked Questions
What does PT101-0100-111-2130 mean?
A Celesco PT101 with 100-inch stroke (0100), standard cable tension (1), top cable exit (1), 1000 Ω potentiometer sensing circuit (2) and a 6-pin metal connector with mating plug (3).
What does the H tension option mean on a PT101?
Order code H selects the high-tension measuring cable (±40% tolerance) — roughly double the standard cable tension (e.g. 26 oz vs 5 oz at the 5-inch range). Choose it when vibration or cable sag could affect reading stability.
How compact is the PT101?
The PT101 body is roughly 2.4 × 2.4 × 1.1 in. with strokes from 2 to 100 inches — one of the smallest cable-extension sensors Celesco makes, common on test benches and medical/fitness equipment.
Found your part number?
Send it to KMBT for a quotation — Celesco cable-extension and rotary position sensors with fast lead times and full datasheets.